![Sony GY-8240FC Скачать руководство пользователя страница 257](http://html.mh-extra.com/html/sony/gy-8240fc/gy-8240fc_maintenance-manual_420972257.webp)
5-41
GY-8240UWD
GY-8240FC
SV1_DIAG=>CH06
"
CH06:Capstan
H:RevMax/J:Rev1x/K:Fwd1x/L:FwdMax/;:Still/':':EXIT
SV1_HJKL;:=>
0000 0000 0000
5-4. DIAG Mode
l.
CH06-Capstan Motor Check
Function:
Checks the functions of the capstan.
Operation:
(1) Without loading any cassette, enter “CH06
"
”. The capstan operation check mode is entered and the
following will be displayed.
By entering the H, J, K, L or “ ; ” key, the capstan motor will operate at the speed listed below.
H:
Capstan reverse maximum speed
J:
Reverse x1 speed
K:
Forward x1 speed
L:
Capstan forward maximum speed
“ ; ”:
Stop
“ : ”:
Exits the capstan operation check mode.
(2) Check the following.
1
Check that when the J key is pressed, the capstan runs in the reverse direction at constant speed.
2
Check that when the K key is pressed, the capstan runs in the forward direction at constant speed.
(3) To end the check, enter “ : ”.
When the above fail:
.
Check the capstan motor drive circuit (SV-205 board).
.
Check the capstan FG output.
.
Check the capstan motor FG amplifier circuit.
Содержание GY-8240FC
Страница 76: ......
Страница 86: ......
Страница 216: ......
Страница 241: ...5 25 GY 8240UWD GY 8240FC Dew sensor Tape top sensor Top view Tape end sensor 5 4 DIAG Mode Sensor Layout ...
Страница 249: ...5 33 GY 8240UWD GY 8240FC Unthread end sensor Threading ring Thread end sensor Threading motor Top view 5 4 DIAG Mode ...
Страница 398: ......
Страница 412: ......
Страница 442: ......
Страница 444: ...Printed in Japan Sony Corporation 2003 2 08 B P Company 2000 GY 8240FC SY GY 8240UWD SY E 9 967 913 06 ...