User Manual of EM730/EM730E Series Inverter
76
0: valid in jogging
1: invalid in jogging
F03.09 Y1 valid delay time
0.000
~
30.000
s
0.000
●
F03.10 Y1 invalid delay time
0.000
~
30.000
s
0.000
●
F03.13 R1 valid delay time
0.000
~
30.000
s
0.000
●
F03.14 R1 invalid delay time
0.000
~
30.000
s
0.000
●
F03.17 Single pulse time of Y1 output
0.001
~
30.000
s
0.250
●
F03.19 Single pulse time of R1 output
0.001
~
30.000
s
0.250
●
F03.21 Options of analog output M1
0: running frequency (absolute value)
1: set frequency (absolute value)
2: output torque (absolute value)
3: set torque (absolute value)
4: output current
5: Output voltage
6: bus voltage
7: output power
8
:
AI1
9
:
AI2
12: High-frequency pulse input (with 100%
corresponding to 100.00kHz)
13: Communication setting 1
14: count value
15: length value
16: PID output
18: PID feedback
19: PID setting
30: Communication setting 2
0
〇
F03.27 M1 output bias
-100.0
~
100.0
%
0.0
●
F03.28 M1 output gain
-10.000
~
10.000
1.000
●
F03.31
Control logic options of PLC
output terminal
D7
D6
D5
D4
D3
D2
D1 D0
0*0
〇
*
*
*
*
*
R1
*
Y1
0: Output
1: no output