![Sinee EM730 Series Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/sinee/em730-series/em730-series_user-manual_1280544072.webp)
User Manual of EM730/EM730E Series Inverter
72
41: process PID pause
42: process PID integral pause
43: PID parameter switching
44: PID positive/negative switching
45: stop and DC braking
46: DC braking at stop
47: immediate DC braking
48: fastest deceleration to stop
49: retention
50: external stop
51: switching of main frequency source to digital
frequency setting
52: switching of main frequency source to AI1
53: Switching of main frequency source to AI2
54: retention
55: Switching of main frequency source to
high-frequency pulse input
56: switching of main frequency source to
communication setting
57: inverter enabling
68: Disable reversal
69: prohibit reversing
121: External material cutoff signal
122: Wiring detection signal
123: Brake reset terminal
F02.15
Positive/negative logic 1 of digital
input terminal
D7
D6 D5
D4
D3
D2
D1
D0
00000
〇
*
*
*
X5
X4
X3
X2
X1
0: positive logic, valid in the closed state/invalid in the
open state
1: Negative logic, invalid in the closed state/valid in the
open state
F02.16
Positive/negative logic 2 of digital
input terminal
D7
D6 D5
D4
D3
D2
D1
D0
00
〇
*
*
*
*
*
*
AI2
AI1
0: positive logic, valid in the closed state/invalid in the
open state
1: Negative logic, invalid in the closed state/valid in the
open state
F02.17
Filtering times of digital input
terminal
0-100, 0: no filtering; n: sampling every n ms
2
〇
F02.18 X1 valid delay time
0.000-30.000
s
0.000
●
F02.19 X1 invalid delay time
0.000-30.000
s
0.000
●
F02.20 X2 valid delay time
0.000-30.000
s
0.000
●
F02.21 X2 invalid delay time
0.000-30.000
s
0.000
●