![Sinee EM730 Series Скачать руководство пользователя страница 141](http://html1.mh-extra.com/html/sinee/em730-series/em730-series_user-manual_1280544141.webp)
User Manual of EM730/EM730E Series Inverter
141
The acceleration time is the time for the output frequency to rise from 0.00Hz to the set
value Fbase of F15.09 (reference frequency of the acceleration and deceleration time); and the
deceleration time is the time for the output frequency to fall from Fbase to 0.00Hz, regardless of
forward and reverse running. See Fig. 7-9.
t1
Output frequency (Hz)
Fbase
Time (s)
t2
Output frequency (Hz)
Fbase
Time (s)
(a) Acceleration time 1 (b) Deceleration time 1
Fig. 7-9 Acceleration and Deceleration Time
Note that the acceleration and deceleration time is in 0.01 s, 0.1 s or 1s, depending
on the F15.13.
Function code
Function code
name
Parameter description
Unit
Default
setting
Attribute
F00.16
Maximum
frequency
1.00
~
600.00
Hz
50.00
〇
The allowable maximum frequency of the inverter is represented by Fmax. The Fmax
range is from 20.00 to 600.00Hz.
Function
code
Function code name
Parameter description
Unit
Default
setting
Attribute
F00.17
Options of upper
frequency limit
control
0: set by F00.18
1: AI1
2: AI2
3: retention
4: retention
5: high frequency pulse input (X5)
6: percent setting of upper limit
frequency communication
7: direct setting of upper limit frequency
communication
0
〇
F00.18
Upper frequency
limit
Lower frequency limit F00.19 to
maximum frequency F00.16
Hz 50.00
●