6: Extruder application
7: High-speed motor
application
F16.00=0: general model
Since the inverter is a general-purpose product, relevant functions for each application
should not be enabled.
F16.00=1: water supply application
Since the inverter is a PID-regulated constant-pressure water supply control product, a
clock option can be provided for clock pressure setting.
F16.00=2: Air compressor application
Since the inverter is a dedicated PID-regulated control product for air compressors, an air
compressor interface option can be provided for PT100 automatic temperature calculation and
the like.
F16.00=3: Winding application
The inverter is a dedicated PID-regulated control product for winding and unwinding.
F16.00=4: Fan application
The inverter can be used to configure the parameters of the corresponding function code for
the fan application macro.
F16.00=5: Machine tool spindle application
The inverter can be used to configure the parameters of the corresponding function code for
the application micro of machine tool spindle.
F16.00=6: Extruder application
The inverter can be used to configure the parameters of the corresponding function code for
the extruder application macro.
F16.00=7: High-speed motor application
The inverter can be used to configure the parameters of the corresponding function code for
the high-speed motor application macro.
After the corresponding application macro is selected by changing the
function code, F12.14 will be executed automatically to restore the default settings,