![Sinee EM730 Series Скачать руководство пользователя страница 284](http://html1.mh-extra.com/html/sinee/em730-series/em730-series_user-manual_1280544284.webp)
User Manual of EM730/EM730E Series Inverter
284
F00.16
Maximum
frequency
75.00Hz
75.00Hz
75.00Hz
50.00Hz
F00.18
Upper
frequency
limit
75.00Hz
75.00Hz
75.00Hz
50.00Hz
F00.20
Reverse
control
1: Prohibit
reversing
0: Allow
forward/reverse
running
1: Prohibit
reversing
0: Allow
forward/reverse
running
F02.00 X1 terminal
1: RUN
1: RUN
1: RUN
1: RUN
F02.01 X2 terminal
89: Reset
feedforward
89: Reset
feedforward
19:
acceleratio
n and
deceleratio
n time
terminal 1
2: FR reverse
F02.02 X3 terminal
121: External
material
cutoff signal
121: External
material cutoff
signal
10: Reset
protection
10: Reset
protection
F02.03 X4 terminal
10: Reset
protection
10: Reset
protection
4: FJOG
26: Frequency
source switching
F02.04
X5 terminal
9: free stop
9: free stop
9: free stop
121: External
material cutoff
signal
F02.57
AI1 filtering
0.05s
0.05s
0.05s
0.05s
F02.58
AI2 filtering
0.00s
0.00s
0.00s
0.00s
F03.00
Y1 Output
3:FDT1
3:FDT1
3:FDT1
68: Material cutoff
detection