![Sinee EM730 Series Скачать руководство пользователя страница 140](http://html1.mh-extra.com/html/sinee/em730-series/em730-series_user-manual_1280544140.webp)
User Manual of EM730/EM730E Series Inverter
140
Fig. 7-8. Both the main frequency source A and the auxiliary frequency source B have a set
gain. When synthesis is selected via the function code F00.06, a synthetic gain will be generated.
The final setting is limited by the analog adjustment and upper and lower frequency limits.
Main frequency source
A setting D00.04, etc.
Auxiliary frequency source B
setting F00.05, etc.
Gain of main frequency
source F00.10
Gain of auxiliary
frequency source F00.11
Synthetic gain of main and
auxiliary frequency sources
(F00.12)
Analog adjustment of
synthetic frequency
(F00.13)
Limit
Synthetic F00.06, etc.
Fig. 7-8 Frequency Source Setting Control (Gain Description)
The gain type function codes (F00.10 to F00.12) are for “multiplication”, i.e. “set value =
original set value * gain”. Below is only the description of the analog adjustment (F00.13).
F00.13=0: synthetic frequency of main and auxiliary channels
The synthetic frequency is directly set to the synthetic frequency of main and auxiliary
channels.
F00.13=1: AI1 * synthetic frequency of main and auxiliary channels
F00.13=2: AI2 * synthetic frequency of main and auxiliary channels
The synthetic frequency is directly set to “AI (percentage) * synthetic frequency of main
and auxiliary channels”.
For the details of AI1-AI2 and X5, refer to the F00.04 description. They have the same
meaning. 100.00% is the percentage relative to the main and auxiliary synthetic frequency.
F00.13=5: High frequency pulse (PULSE) * synthetic frequency of main and auxiliary
channels
The synthetic frequency is directly set to “HDI (percentage) * synthetic frequency of main
and auxiliary channels”.
For the details of AI1-AI2 and X5, refer to the F00.04 description. They have the same
meaning. 100.00% is the percentage relative to the main and auxiliary synthetic frequency.
Function
code
Function code name
Parameter description
Unit
Default
setting
Attribute
F00.14
Acceleration time 1
0.00 - 650.00 (F15.13=0)
0.0 - 6500.0 (F15.13=1)
0 - 65000 (F15.13=2)
s
15.00
●
F00.15
Deceleration time 1
0.00 - 650.00 (F15.13=0)
0.0 - 6500.0 (F15.13=1)
0 - 65000 (F15.13=2)
s
15.00
●