non-workers, the keyboard has a parameter locking function. The current function code is
unlocked by default, and all function codes can be set. After the function code is debugged
according to the working conditions, the parameters can be locked.
1: reference input not locked
In the lock mode, all function codes cannot be modified, expect this function code and those
with reference input properties. Specific function codes with parameter input properties are
shown in Table 7-19:
Table 7-19 List of Function Codes with Reference Input Properties
Function code
Function code name
Function code
Function code name
F00.07
Digital frequency setting
F08.11
Multi-segment speed 12
F08.00
Multi-segment speed 1
F08.12
Multi-segment speed 13
F08.01
Multi-segment speed 2
F08.13
Multi-segment speed 14
F08.02
Multi-segment speed 3
F08.14
Multi-segment speed 15
F08.03
Multi-segment speed 4
F13.02
Digital torque setting
F08.04
Multi-segment speed 5
F09.01
Digital PID setting
F08.05
Multi-segment speed 6
F09.32
Multi-segment PID setting 1
F08.06
Multi-segment speed 7
F09.33
Multi-segment PID setting 2
F08.07
Multi-segment speed 8
F09.34
Multi-segment PID setting 3
F08.08
Multi-segment speed 9
F13.03
Multi-segment torque 1
F08.09
Multi- speed 10
F13.04
Multi-segment torque 2
F08.10
Multi-segment speed 11
F13.05
Multi-segment torque 3
2: all locked, except for this function code
In the lock mode, all function codes cannot be set except this function code. This mode is
mostly used when it is not necessary to set parameters after debugging. We can only perform
running, stop and parameter monitoring in this mode.
We can press the ESC key
to enable the monitoring mode (see 4.4When the
inverter is in the protection status, you can directly press the right shift
current protection type and the output frequency, output current, output voltage, running status
and working time during the protection.
Operation Monitoring: press the right shift key
to display the parameters in cycles.
The function codes F12.04 to F12.08 are used to select the parameters to be displayed in the
cycle display queue. The selected items basically correspond to the monitoring parameter group
of the F18 group, so you can directly view the current values of all parameters in the F18 group.