When the motor wiring distance exceeds 50 m, connect the output terminals (U, V, W) of the
inverter with the dedicated AC reactor (phase capacity: the same as that of the inverter) for
inverter output.
Table3-2 Wiring Distance and Carrier Frequency between Inverter and Motor
Wiring distance between inverter and
motor
<50m
<100m
>100m
Carrier frequency
Below 10kHz
Below 8kHz
Below 5kHz
Function code F00.23
10.0
8.0
5.0
3.2.6
Cable and screw dimensions of main circuit
The cable and screw dimensions of the main circuit are shown in Table 3-3.
Table3-3 Cable Dimensions and Terminal Screw Specifications
Frequency converter
model
Terminal Symbol
Terminal
Screw
Tightening
Torque
(N.m)
Wire
diameter
(mm²
)
Wire Type
EM730/EM730E-0R4-2B
PB, +, -, R, S, T, U, V,
W
M3
0.5
~
0.7
1.5
750V
wire
EM730/EM730E-0R7-2B
EM730/EM730E-0R7-3B
EM730/EM730E-1R5-3B
EM730/EM730E-1R5-2B
M4
1.5
~
2.0
EM730/EM730E-2R2-2B
4
EM730/EM730E-2R2-3B
EM730/EM730E-4R0-3B
EM730/EM730E-5R5-3B
6
EM730/EM730E-7R5-3B
EM730/EM730E-011-3B
M5
3.0
~
4.0
10
EM730/EM730E-015-3B
EM730/EM730E-018-3B
EM730/EM730E-022-3B
16
EM730/EM730E-030-3B
R, S, T, PB, +, -, U, V,
W,
M6
4.0
~
5.0
25
EM730/EM730E-037-3B
EM730/EM730E-030-3
EM730/EM730E-037-3
EM730/EM730E-045-3
R, S, T, +, -, U, V, W,
M8
9.0
~
10.0
35
EM730/EM730E-055-3
35
EM730/EM730E-075-3
60