User Manual of EM730/EM730E Series Inverter
278
X5
X4
X3
X2
X1
0/1
0/1
0/1
0/1
0/1
The actual display effect is: 00000.
★
: “0” means that the current terminal function is
invalid; and “1” means that the current terminal function
is valid.
F18.23
Digital input
terminal status 2
Display the current valid status of the input terminals AI1
and AI2. The five-bit digit tubes from left to right are:
*
AI2
AI1
*
*
0/1
0/1
0/1
0/1
0/1
The actual display effect is: 0000.
★:
The analog input terminals AI1 and AI2 of the
EM730/EM730E series inverter can be used for digital
input only.
“0” means that the current terminal function is invalid;
and “1” means that the current terminal function is valid.
F18.25
Output terminal
state
Display the current valid status of the output terminals
R1/Y1. The five-bit digital tubes from left to right are:
*
*
R1
*
Y1
0/1
0/1
0/1
0/1
0/1
The actual display effect is: 000.
“0” means that the current function terminal is invalid;
and “1” means that the current function terminal is valid.
F18.26 AI1
Display the per-unit value of the current analog input
channel 1 (AI1) relative to 100.0%. Scope: -100.0 - 100.0
%
F18.27 AI2
Display the per-unit value of the current analog input
channel 2 (AI2) relative to 100.0%. Scope: 0.0 - 100.0.
%
F18.30 Reserved
F18.31
High-frequency
pulse input
frequency: kHz
0.00-100.00
kHz
F18.32
High-frequency
pulse input
frequency: Hz
0~65535
Hz
F18.33 Count value
0~65535
F18.34 Actual length
0~65535
m
F18.35
Remaining time
of regular running
Display the remaining time of regular running. For
specific function. see the description of the F16.05
regular running function. Scope: 0.0 - F16.05.
min
F18.36
Rotor position of
synchronous
0.0~359.9°