![Sinee EM730 Series Скачать руководство пользователя страница 135](http://html1.mh-extra.com/html/sinee/em730-series/em730-series_user-manual_1280544135.webp)
User Manual of EM730/EM730E Series Inverter
135
Table 7-3 Detailed Setting of Main Frequency Source A
Terminal Function
Status Description
Priority
11-14: multi-segment speed
terminals 1-4
If one is valid, the multi-segment speed mode will be
enabled (F08.00-F08.14).
1
51: switching of main
frequency source to digital
frequency setting
Valid, depending on the digital frequency setting
F00.07, the same as the function code F00.04=0
2
52: switching of main
frequency source to AI1
Valid, depending on the AI1 input percentage setting,
the same as the function code F00.04=1
3
53: Switching of main
frequency source to AI2
Valid, depending on the AI2 input percentage setting,
the same as the function code F00.04=2
4
56: switching of main
frequency source to
communication setting
Valid, depending on the communication input, the same
as the function code F00.04=6
7
--
All invalid, depending on the setting of function code
F00.04
8
F00.05=0: digital frequency setting F00.07
The auxiliary frequency B depends on the digital frequency setting F00.07.
F00.05=1:AI1
F00.05=2:AI2
The auxiliary frequency B is determined by AI (percentage) * F00.16.
For the details of AI1 and AI2, refer to the F00.04 description. They have the same
Function
code
Function code name
Parameter description
Unit
Default
setting
Attribute
F00.05
Options of auxiliary
frequency source B
0: digital frequency setting
F00.07
1: AI1
2: AI2
3: retention
4: retention
5: high frequency pulse input
(X5)
6: percent setting of auxiliary
frequency communication
7: direct setting of auxiliary
frequency communication
8: digital potentiometer setting
9: retention
10: process PID
11: simple PLC
0
〇