User Manual of EM730/EM730E Series Inverter
342
Fig. 4-24 485 Schematic Diagram of Network Link Data
11.5
Examples
1)
Forward running of inverter
Send:
01 41 70 0000 01 E6 C5
Return:
01 41 70 0000 01 E6 C5 (normal)
Return:
01 C1 04 70 53 (exception, assuming a slave protection)
Send the invoice to
Normal Return
Exception Return
* Frame header
≥3.5 characters (idle)
1 Address
01 Address
01 Address
01
2 Function code
41 Function code
41 Function code
C1
3 Register address Hi
70 Register address Hi
70 Exception code
04 (assumption)
4 Register address Lo 00 Register address Lo
00 CRC check Lo
70
5 Register value Hi
00 Register value Hi
00 CRC check Hi
53
6 Register value Lo
01 Register value Lo
01
7 CRC check Lo
E6 CRC check Lo
E6
8 CRC check Hi
C5 CRC check Hi
C5
* Tail
≥3.5 characters (idle)
2)
Free stop of inverter
Send:
01 41 70 0000 07 66 C7
Return:
01 41 70 0000 07 66 C7 (normal)
Return:
01 C1 04 70 53 (exception, assuming a slave protection)
Send the invoice to
Normal Return
Exception Return
* Frame header
≥3.5 characters (idle)
1 Address
01 Address
01 Address
01
2 Function code
41 Function code
41 Function code
C1
3 Register address Hi
70 Register address Hi
70 Exception code
04 (assumption)
4 Register address Lo 00 Register address Lo
00 CRC check Lo
70
5 Register value Hi
00 Register value Hi
00 CRC check Hi
53
6 Register value Lo
07 Register value Lo
07