Frame
size
Height
Height in‐
cluding
shield
plate
1)
Width
Depth
Additional depth
Clearance
2)
With oper‐
ator panel
With G120
Smart Ac‐
cess
A
B
lateral
front
FSH
1487
-
548
410
-
-
200
200
30
100
FSJ
1438
-
801
410
-
-
200
200
30
100
1)
The shield plates for FSD to FSG are available as options only.
2)
The cooling air clearances A and B refer to the converter without shield plate.
3)
Maximum surrounding air temperature during operation dependent on lateral clearance:
- Max. 55 °C for mounting with 0 mm lateral clearance (for tolerance reasons, we recommend a lateral clearance of approx.
1 mm.)
- Max. 60 °C for mounting with 50 mm lateral clearance.
Drill patterns (mm)
Table 3-1
FSA … FSG
Drill pattern
Dimensions
FSA
FSB
FSC
FSD
FSE
FSF
FSG
$
%
A
55
80
118
170
230
270
265
B
221.5
265
283
430
509
680
970.5
Ø
5
5
5.5
6.0
6.5
8.5
12.0
Fixings (bolts,
washers, nuts)
4 × M4
4 × M4
4 × M5
4 × M5
4 × M6
4 × M8
4 × M10
Tightening torque
(Nm)
2.5
2.5
2.5
6
10
25
50
Note: For the converters FSD to FSG, a printed drill pattern is supplied with each converter. This can be used to easily drill the
necessary mounting holes.
Mounting
3.3 Mounting the converter
SINAMICS G120XA converter
48
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Содержание SINAMICS G120XA
Страница 2: ......
Страница 12: ...Table of contents SINAMICS G120XA converter 10 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 104: ...Wiring 4 2 Control interfaces SINAMICS G120XA converter 102 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 916: ...Index SINAMICS G120XA converter 914 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 917: ......