p1041[0...n]
BI: Motorized potentiometer manual/automatic / Mop manual/auto
Access level: 3
Calculated: -
Data type: Unsigned32 / Binary
Can be changed: T
Scaling: -
Dynamic index: CDS, p0170
Unit group: -
Unit selection: -
Function diagram: 3020
Min:
-
Max:
-
Factory setting:
0
Description:
Sets the signal source to change over from manual to automatic when using a motorized potentiometer.
In the manual mode, the setpoint is changed using two signals - raise and lower. In the automatic mode, the setpoint
must be interconnected via a connector input.
Dependency:
See also: p1030, p1035, p1036, p1042
Note
The effectiveness of the internal ramp-function generator can be set in automatic mode.
p1042[0...n]
CI: Motorized potentiometer automatic setpoint / Mop auto setpoint
Access level: 3
Calculated: -
Data type: Unsigned32 /
FloatingPoint32
Can be changed: T
Scaling: p2000
Dynamic index: CDS, p0170
Unit group: -
Unit selection: -
Function diagram: 3020
Min:
-
Max:
-
Factory setting:
0
Description:
Sets the signal source for the setpoint of the motorized potentiometer in the automatic mode.
Dependency:
See also: p1041
p1043[0...n]
BI: Motorized potentiometer accept setting value / MotP acc set val
Access level: 3
Calculated: -
Data type: Unsigned32 / Binary
Can be changed: T
Scaling: -
Dynamic index: CDS, p0170
Unit group: -
Unit selection: -
Function diagram: 3020
Min:
-
Max:
-
Factory setting:
0
Description:
Sets the signal source to accept the setting value for the motorized potentiometer.
Dependency:
See also: p1044
Note
The setting value (CI: p1044) becomes effective for a 0/1 edge of the setting command (BI: p1043).
p1044[0...n]
CI: Motorized potentiometer setting value / Mop set val
Access level: 3
Calculated: -
Data type: Unsigned32 /
FloatingPoint32
Can be changed: T
Scaling: p2000
Dynamic index: CDS, p0170
Unit group: -
Unit selection: -
Function diagram: 3020
Min:
-
Max:
-
Factory setting:
0
Description:
Sets the signal source for the setting value for the motorized potentiometer.
Dependency:
See also: p1043
Note
The setting value (CI: p1044) becomes effective for a 0/1 edge of the setting command (BI: p1043).
Parameters
7.3 Parameters
SINAMICS G120XA converter
470
Operating Instructions, 03/2019, FW V1.0, A5E44751205B AB
Содержание SINAMICS G120XA
Страница 2: ......
Страница 12: ...Table of contents SINAMICS G120XA converter 10 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 104: ...Wiring 4 2 Control interfaces SINAMICS G120XA converter 102 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 916: ...Index SINAMICS G120XA converter 914 Operating Instructions 03 2019 FW V1 0 A5E44751205B AB ...
Страница 917: ......