The Spectrum Application (RF Measurements)
R&S
®
FPL1000
96
User Manual 1178.3370.02 ─ 09
7.2
Measurements and Results
Access
: "Overview" > "Select Measurement"
Or
: [MEAS]
In the Spectrum application, the R&S
FPL1000 provides a variety of different measure-
ment functions.
●
Basic measurements
- measure the spectrum of your signal or watch your signal
in time domain
●
Power measurements
- calculate the powers involved in modulated carrier signals
●
Emission measurements
- detect unwanted signal emission
●
Statistic measurements
- evaluate the spectral distribution of the signal
●
Special measurements
- provide characteristic values of the signal
●
EMI measurements
- detect electromagnetic interference in the signal
The individual functions are described in detail in the following chapters.
The measurement function determines which settings, functions and evaluation meth-
ods are available in the R&S
FPL1000. The various measurement functions are descri-
bed in detail here.
When you select a measurement function, the measurement is started with its default
settings immediately and the corresponding measurement configuration menu is dis-
played. The measurement configuration menu can be displayed at any time by press-
ing the [MEAS CONFIG] key.
The easiest way to configure measurements is using the configuration "Overview", see
Chapter 7.1, "Configuration Overview"
In addition to the measurement-specific parameters, the general parameters can be
configured as usual, see
Chapter 7, "The Spectrum Application (RF Measurements)"
on page 94. Many measurement functions provide special result displays or evaluation
methods; however, in most cases the general evaluation methods are also available,
see
Chapter 7.2.2, "Basic Evaluation Methods"
In addition to the measurement-specific parameters, the general parameters can be
configured as usual, see
Chapter 7.1, "Configuration Overview"
measurement functions provide special result displays or evaluation methods; how-
ever, in most cases the general evaluation methods are also available, see
ter 7.2.2, "Basic Evaluation Methods"
The remote commands required to retrieve measurement results are described in
Chapter 11.8.7.4, "Retrieving Trace Results"
...............................................................................................97
..................................................................................... 117
............................................................................... 119
Channel Power and Adjacent-Channel Power (ACLR) Measurement
............................................................................149
Occupied Bandwidth Measurement (OBW)
.......................................................... 152
Spectrum Emission Mask (SEM) Measurement
................................................... 159
Spurious Emissions Measurement
........................................................................199
Measurements and Results