![Ronde & Schwarz 1304.0004.03 Скачать руководство пользователя страница 986](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004-03/1304-0004-03_user-manual_1484985986.webp)
Remote Commands
R&S
®
FPL1000
986
User Manual 1178.3370.02 ─ 09
Command
Supported subset
Function
Corresp. HP-
Models
Status
FA
FA <numeric_value> HZ|
KHZ|MHZ|GHZ
FA UP
FA DN
FA?
Start Frequency
HP 8566A/
HP 8568A/
HP 856xE/
HP 8566B/
HP 8568B/
HP 8594E
available
FB
FB <numeric_value> HZ|
KHZ|MHZ|GHZ
FB UP
FB DN
FB?
Stop Frequency
HP 8566A/
HP 8568A/
HP 856xE/
HP 8566B/
HP 8568B/
HP 8594E
available
FDSP
Frequency display off
8560E
8561E
8562E
8563E
8564E
8565E
available
FOFFSET
1)
FOFFSET
<numeric_value> HZ|
KHZ|MHZ|GHZ
FOFFSET?
Frequency Offset
HP 856xE/
HP 8566B/
HP 8568B/
HP 8594E
available
FREF
FREF INT|EXT
Reference Frequency
HP 856xE/
HP 8566B/
HP 8568B/
HP 8594E
available
FS
FS
Full Span
HP 8566A/
HP 8568A
available
FUNCDEF
Define Function Function
must be in one line
between delimiters @
HP 8594E/
HP 856xE/
HP 8566B
available
GATE
1)
GATE ON|OFF
GATE 1|0
HP 856xE/
HP 8566B/
HP 8568B/
HP 8594E
available
GATECTL
1)
GATECTL EDGE|LEVEL
GATECTL?
HP 856xE/
HP 8566B/
HP 8568B/
HP 8594E
available