![Ronde & Schwarz 1304.0004.03 Скачать руководство пользователя страница 870](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004-03/1304-0004-03_user-manual_1484985870.webp)
Remote Commands
R&S
®
FPL1000
870
User Manual 1178.3370.02 ─ 09
<m>
Parameters:
<State>
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
CALC:DELT:FUNC:FIX ON
Switches on the measurement with fixed reference value for all
delta markers.
CALC:DELT:FUNC:FIX:RPO:X 128 MHZ
Sets the frequency reference to 128 MHz.
CALC:DELT:FUNC:FIX:RPO:Y 30 DBM
Sets the reference level to +30 dBm.
Manual operation:
See
11.8.8.8
Marker Peak Lists
Useful commands for peak lists described elsewhere
●
CALCulate<n>:MARKer<m>:PEXCursion
●
●
Chapter 11.8.8.3, "Configuring and Performing a Marker Search"
Remote commands exclusive to peak lists
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:ANNotation:LABel[:STATe]
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:COUNt?
...................................................871
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks[:IMMediate]
.............................................. 871
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:LIST:SIZE
.................................................872
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:SORT
...................................................... 872
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:STATe
......................................................872
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:X?
........................................................... 873
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:Y?
........................................................... 873
CALCulate<n>:MARKer<m>:FUNCtion:FPEaks:ANNotation:LABel[:STATe]
<State>
This command turns labels for peaks found during a peak search on and off.
The labels correspond to the marker number in the marker peak list.
Suffix:
<n>
.
<m>
Setting Basic Spectrum RF Measurement Parameters