![Rohde & Schwarz FPL1000 Series Скачать руководство пользователя страница 747](http://html.mh-extra.com/html/rohde-and-schwarz/fpl1000-series/fpl1000-series_user-manual_1477826747.webp)
Remote Commands
R&S
®
FPL1000
747
User Manual 1178.3370.02 ─ 03
CALCulate<n>:MARKer<m>:FUNCtion:PNOise[:STATe]
<State>
This command turns the phase noise measurement at the marker position on and off in
the Analog Demodulation application.
Suffix:
<n>
.
<m>
Parameters:
<State>
ON | OFF | 1 | 0
*RST:
0
Example:
CALC:MARK2:FUNC:PNO ON
Switches on the phase-noise measurement for the marker 2.
8.8.8.11
Band Power Marker
The following commands control the marker for band power measurements.
Using Markers
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:MODE
.................................................... 747
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:RESult?
..................................................748
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:SPAN
.....................................................748
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer[:STATe]
..................................................748
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:MODE
<Mode>
This command selects the way the results for a band power marker are displayed.
(Note: relative power results are only availabe for delta markers, see
DELTamarker<m>:FUNCtion:BPOWer:MODE
Suffix:
<n>
.
<m>
Parameters:
<Mode>
POWer
Result is displayed as an absolute power. The power unit
depends on the
setting.
DENSity
Result is displayed as a density in dBm/Hz.
*RST:
POWer
Example:
CALC:MARK4:FUNC:BPOW:MODE DENS
Configures marker 4 to show the measurement results in
dBm/Hz.
Manual operation:
See
Setting Basic Spectrum RF Measurement Parameters