8.8.4.1
Configuring the Triggering Conditions
The following commands are required to configure a triggered measurement.
...........................................................................................663
TRIGger[:SEQuence]:HOLDoff[:TIME]
..............................................................................663
TRIGger[:SEQuence]:IFPower:HOLDoff
........................................................................... 663
TRIGger[:SEQuence]:IFPower:HYSTeresis
...................................................................... 664
TRIGger[:SEQuence]:LEVel[:EXTernal<port>]
.................................................................. 664
TRIGger[:SEQuence]:LEVel:IFPower
............................................................................... 664
TRIGger[:SEQuence]:LEVel:IQPower
.............................................................................. 665
.......................................................................................... 665
........................................................................................665
TRIGger[:SEQuence]:TIME:RINTerval
............................................................................. 666
TRIGger[:SEQuence]:DTIMe
<DropoutTime>
Defines the time the input signal must stay below the trigger level before a trigger is
detected again.
Parameters:
<DropoutTime>
Dropout time of the trigger.
Range:
0 s to 10.0 s
*RST:
0 s
Manual operation:
See
TRIGger[:SEQuence]:HOLDoff[:TIME]
<Offset>
Defines the time offset between the trigger event and the start of the sweep.
A negative offset is possible for time domain measurements.
For the trigger sources "External" or "IF Power", a common input signal is used for both
trigger and gate. Therefore, changes to the gate delay will affect the trigger offset as
well.
Parameters:
<Offset>
For measurements in the frequency domain, the range is 0
s to
30
s.
For measurements in the time domain, the range is the negative
sweep time to 30
s.
*RST:
0 s
Example:
TRIG:HOLD 500us
Manual operation:
See
TRIGger[:SEQuence]:IFPower:HOLDoff
<Period>
This command defines the holding time before the next trigger event.
Setting Basic Spectrum RF Measurement Parameters