Chapter 4: Programming
72
Phason
Example 2
Example 2 shows how you can use the two setback
groups (
A
and
B
) to have two different setback values for
different zones.
The setback for zones 1 and 2 is 5.0°F between 6:00 AM
and 9:00 PM. If the
group set point
for zones 1 and 2 is
78.0°F:
From 6:00 AM to 9:00 PM, the
adjusted set point
for
zones 1 and 2 will be 73.0°F.
After 9:00 PM and before 6:00 AM, the
set point
would be the normal 78.0°F.
The setback for zones 3 and 4 is 8.0°F between 6:00 AM
and 6:00 PM. If the
group set point
for zones 3 and 4 is
80.0°F:
From 6:00 AM to 6:00 PM, the
adjusted set point
for zones 3 and 4 will be 72.0°F.
After 6:00 PM and before 6:00 AM, the
set point
would be the normal 80.0°F.
on page 133 when programming
temperature setback.
To program the temperature setback
1.
From the Main Menu, select
Settings
(1).
2.
From the Settings menu, select
Temp Setback
.
The display should look like the following example; this is setback A. If you want to define
setback B, scroll down until you see
TEMP SETBACK B
on the top line.
3.
Scroll to
Zone
and then press
ENTER
.
4.
Press
+
or
–
to select the zone(s) affected by the setback and then press
ENTER
.
5.
Scroll to
Status
and then press
ENTER
.
6.
Press
+
or
–
to toggle between
Disabled
and
Enable
and then press
ENTER
.
7.
Scroll to
Setback
and then press
ENTER
.
TEMP SETBACK A
Zone: None
Status: Disabled
Setback: 5.0°F
TEMP SETBACK A
Zone: 1&2
Status: Enabled
Setback: 5.0°F
Start Time: 6:00 AM
Stop Time:
9:00 PM
TEMP SETBACK B
Zone: 3&4
Status: Enabled
Setback: 8.0°F
Start Time: 6:00 PM
Stop Time:
6:00 PM