Connecting equipment to the Supra
21040012
27
To connect curtain machines
Connect curtain machines to the Supra as shown.
Connecting single-stage heating or cooling elements
Heating or cooling elements include equipment such as electric heaters, furnaces, single-speed fans,
and curtains.
Appendix D: Installation worksheet
on page 123 and
Appendix E: Configuration worksheets
on page 125 when installing single-stage
heating or cooling elements.
Supra relay ratings
: 10 A at 120/230 VAC, general-purpose (resistive)
1/3 HP at 120 VAC, 1/2 HP at 230 VAC
360 W tungsten at 120 VAC
If you are connecting equipment that exceeds the relay ratings, you must install
a power contactor. For more information, read
increase the capacity of relays
Gas furnaces using hot-surface ignition or glow plug can draw more current than
indicated on their nameplate and require power contactors. For more
information, read your furnace manual.