Appendix F: Settings worksheets
21040012
137
Curtain worksheet
Curtains control the temperature by adjusting the air flow into the facility. Each curtain has six
settings.
Set point – the temperature at which the curtain holds its position.
Idle band – the buffer around the set point within which the curtains hold their position.
Open run time – the duration the curtains open during the ON cycle
Open idle time – the duration the curtains hold their position during the ON cycle
Close run time – the duration the curtains open during the OFF cycle
Close idle time – the duration the curtains hold their position during the OFF cycle
Programming curtain control relays
Curtain
Zone
Set point
Idle band
Open run
Open idle
Close run
Close idle
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
Temperature in °F/°C, range:
–
10 to 43°C (14 to 110°F)
Duration in mm:ss, range: 0 to 10 minutes in 1 second increments