Appendix C: Factory defaults
122
Phason
Appendix C: Factory defaults
When the Supra leaves the factory, it comes with default settings and configuration. When you
configure and set up the Supra, you change its settings. Resetting the Supra erases
all the configuration
and settings you programmed
and then restores the settings to what they were when the control left the
factory. For more information, read
Resetting the Supra to its factory defaults
The following table lists the factory defaults.
Configuration defaults
Relays
(1 to 12)
Zone:
1
Mode:
unassigned
Tunnel turn off:
no
Variable stages
(1 to 4)
Zone:
1
Mode:
cool
Tunnel turn off:
no
Hum zone
Unassigned
Variable DC outputs
(1 to 4)
Zone:
1
Mode:
cool
Tunnel turn off:
no
Settings menu defaults
Group setpoint
Zone 1:
85.0°F
Zone 2:
85.0°F
Zone 3:
85.0°F
Zone 4:
85.0°F
Growth curve
(A and B)
Zone:
None
Status:
Disabled
Current day:
1
Step 1:
day 1 85.0°F
Step 2:
day 4 80.0°F
Step 3:
day 14 75.0°F
Step 4:
day 24 70.0°F
Step 5:
day 34 65.0°F
Step 6:
day 44 60.0°F
Step 7:
day 64 60.0°F
Heat/cool stages
None assigned
Variable stages
(1 to 4)
On full at:
86.5°F
Idle at:
85.0°F
Off at:
80.0°F
Idle speed:
20%
Curtains
None assigned
Actuators
None assigned
Alarms
Probe 1:
Enabled
Probe 2-4:
Disabled
High temp:
99.0°F
Low temp:
50.0°F
Biasing enabled:
No
High temp bias:
10.0°F
Bias time:
1 hour
Probe damage:
Yes
AC power:
Yes
AC frequency:
Yes
Actuator jam:
Yes
PC comms:
No
Water overflow:
No
Max flow:
500000
Sensor damage:
No
Silencing:
30:00
Min duration:
01:00
Duty cycle
None assigned
Timed events
None assigned
Water meter
1 Litre/pulse
Display in:
Litres
Humidity control
Upper limit:
90%
Lower limit:
30%
Temp setback
(A and B)
Zone:
None
Status:
Disabled
Setback:
5.0°F
Start Time:
6:00 AM
Stop Time:
9:00 PM
Tunnel mode
Setpoint:
85.0°F