Chapter 3: Configuration
56
Phason
3.
To change the zone the element will be controlling, place the cursor on the Zone line and then
press
ENTER
. Press
+
or
–
to change the zone and then press
ENTER
.
4.
Scroll to the Mode line and then press
ENTER
.
5.
Press
+
or
–
until you see
Duty Cycle
and then press
ENTER
.
6.
Scroll to
Tunnel turn off
and then press
ENTER
.
7.
Press
+
or
–
to select
Yes
(off during tunnel mode) or
No
(can be on during tunnel mode)
and then press
ENTER
.
8.
Scroll to the Name line and then press
ENTER
.
9.
Enter the name (maximum 13 characters) for this relay. For more information, read
on page 17. To save the name, press
ENTER
until the cursor returns to the
beginning of the line. To cancel the change, press
BACK
.
10.
Repeat steps 2 to 9 for each time-based duty cycle element you have connected to the Supra.
11.
Press
BACK
to return to the Main Menu.
Configuring relays for timed events
Relays configured for timed events can be used to control feed augers, turn lights on and off, or
control equipment that must operate at specific times each day, regardless of temperature. An
example of a timed event would be would be switching the yard lights on at 8:00 PM and off at 7:00
AM.
Tunnel mode has no effect for timed events.
on page 125 when configuring relays.
To configure timed event relays
1.
From the Main Menu, select
Configuration
(5).
2.
Scroll to the relay you want to configure.
The display should look like the following example.
Zone
Mode
Tunnel option (
yes
is enabled;
no
is not enabled)
Name
_Relay 1 Zone 1
Unassigned
Tunnel turn off? No
Name: Rly 01