Chapter 3: Configuration
54
Phason
8.
Scroll to the Name line and then press
ENTER
.
9.
Enter the name (maximum 13 characters) for this relay. For more information, read
on page 17. To save the name, press
ENTER
until the cursor returns to the
beginning of the line. To cancel the change, press
BACK
.
10.
Repeat steps 2 to 9 for each heating or cooling element you have connected to the Supra.
11.
Press
BACK
to return to the Main Menu.
Configuring relays for curtains
Curtains are usually controlled by equipment called curtain machines (sometimes referred to as
winches). Curtains are opened and closed to let in more air or less air. The idea is more air cools the
building.
You can connect up to six curtain machines to the Supra. Each curtain machine you connect
requires two relays: one for opening the curtain, and one for closing the curtain. You can connect
curtain machines to any of the available relays, but side-by-side relays are recommended.
on page 125 when configuring relays.
To configure relays for curtains
These steps use Curtain 1. If you are configuring additional curtains, follow the
same steps, but use the appropriate number in place of Curtain 1.
If you are configuring the curtain to close during tunnel mode, configure both the
open and close relays.
1.
From the Main Menu, select
Configuration
(5).
2.
Scroll to the relay you want to configure for opening the curtain.
The display should look like the following example.
3.
To change the zone the curtain will be controlling, place the cursor on the Zone line and then
press
ENTER
. Press
+
or
–
to change the zone and then press
ENTER
.
4.
Scroll to the Mode line and then press
ENTER
.
Zone
Mode
Tunnel option (
yes
is enabled;
no
is not enabled)
Name
_Relay 1 Zone 1
Unassigned
Tunnel turn off? No
Name: Rly 01