Programming the stages
21040012
89
For example, you can have a feed auger run for 15 minutes and then stop for 45 minutes between
6:00 AM and 8:00 PM. In other words, “Between 6:00 AM and 8:00 PM, I want the feed auger ON
for 15 minutes, OFF for 45 minutes, ON for 15 minutes… and so on.”
This section explains how to set up time-based duty cycles. If you want to set up
temperature-based duty cycles (duty cycles that operate for specific durations while
the temperature is above or below a certain value), see
on page 83. If you want to set up elements that turn on and off at
Time-based duty cycle worksheet
on page 141 when setting up time-based
duty cycles.
To set up time-based duty cycles
1.
From the Main Menu, select
Settings
(1)
2.
From the Settings menu, select
Duty Cycle
(8).
The display should look like the following example.
The first line is the name you gave the relay when you configured it. Only relays that have been
configured as timed events appear in the display. To program other timed event relays, scroll
down until the name is on the top line.
3.
Scroll to the second line, and press
ENTER
.
The relay does not switch on until the “from” time (start time).
The relay switches off (if it is not off already) at the “to” time (end time) and does not switch on again until the time
reaches the start
time.
ON duration
ON duration
OFF duration
OFF duration
15 minutes
15 minutes
45 minutes
45 minutes
ON
OFF
All ON durations are the same
All OFF durations are the same
Feeder 1
On 15:00 Off 45:00
From 6:00 AM
To 8:00 PM
Name
Duty cycle
Starts at this time
Ends at this time