Monitoring the Supra
21040012
101
5.
Look up the meaning of the alarm(s) in the table on page 117 and then follow the instructions in
the table.
When troubleshooting temperature probe problems, make sure you are
troubleshooting the correct probe. Probe 1 does not necessarily mean Zone 1.
Refer to your configuration and installation worksheets.
Reading the daily log
The Supra stores information about environmental conditions periodically in a log file called the
daily log. The Supra stores outside temperatures, zone temperatures, humidity, water usage, and relay
ON durations.
The following image explains each item on the daily log.
July 7 11:59 PM
Zone 1 72.7 78.9
Zone 2 73.4 80.2
Zone 3 72.5 78.4
Zone 4 ---- ----
Outside 68.5 82.3
Humidity 75% 86%
Water 2340 Gal
Relay 1
2:03
Relay 2
2:10
Relay 3
0:34
Relay 4
1:12
Relay 5
8:56
Relay 6
10:03
Relay 7
4:48
Relay 8
7:30
Relay 9
0:05
Relay 10
0:55
Relay 11
0:00
Relay 12
0:00
Date and time of the log
Minimum and maximum outdoor temperatures
Total water usage for the day
Minimum and maximum humidity
Total relay ON durations for the day
Minimum and maximum temperatures for zones 1 to 4