Chapter 5: Monitoring
108
Phason
Testing equipment connected to relays
The Supra has two displays for testing equipment connected to relays: one for viewing the states
(ON or OFF) and one for manually testing the equipment connected to each relay. The relay tests
are useful for detecting faulty connections or configuration errors.
Before testing equipment connected to relays, make sure you know what is
connected to each relay. Testing relays without knowing which equipment is
connected to them can damage your equipment. For example, switching on an
actuator’s open and close relays at the same time can damage the
actuator
power supply and the Supra’s relays
.
For more information about what is connected to the Supra, see your installation
worksheets.
To test equipment connected to relays
1.
From the Main Menu, select
Diagnostics
(6).
2.
From the Diagnostics menu, select
View relay Stages
(3).
The display should look like the following example.
If a relay is closed, the display shows
On
next to the relay. If a relay is open, the display shows
Off
next to the relay.
3.
Confirm the equipment is producing the proper output for the current relay state. Go to the
equipment connected to each stage and check that it is on if the state displays
On
, or off if the
state displays
Off
.
If the displayed states are correct, go to step 9. If any are incorrect, go to the next step.
4.
Press
BACK
to return to the Diagnostics menu and then select
Set relay Stages
(4).
All relay stages switch off. The display should look like the following example.
1 On 5 On 9 Off
2 On 6 Off 10 Off
3 Off 7 On 11 Off
4 Off 8 Off 12 Off
Press
Up
or
Down
to scroll through the lines.
Press
ENTER
to scroll from left to right on a line.
1 Off 5 Off 9 Off
2 Off 6 Off 10 Off
3 Off 7 Off 11 Off
4 Off 8 Off 12 Off