Chapter 3: Configuration
50
Phason
3.
To change the zone the actuator will be controlling, place the cursor on the Zone line and then
press
ENTER
. Press
+
or
–
to change the zone and then press
ENTER
.
4.
Scroll to the Mode line and then press
ENTER
.
5.
Press
+
or
–
until you see
Actuator 1 Open
(or
Actuator 1 Close
for
the closing relay) and then press
ENTER
.
6.
Scroll to
Tunnel turn off
and then press
ENTER
.
7.
Press
+
or
–
to select
Yes
(actuator closes the inlet during tunnel mode) or
No
(actuator
reacts normally during tunnel mode) and then press
ENTER
.
8.
Scroll to the Name line and then press
ENTER
.
9.
Enter the name (maximum 13 characters) for this relay. For more information, read
on page 17. To save the name, press
ENTER
until the cursor returns to the
beginning of the line. To cancel the change, press
BACK
.
10.
Repeat steps 2 to 9 using the relay you want to configure for closing the actuator.
11.
Press
BACK
to return to the Main Menu.
12.
Go to the section
Calibrating actuators
After configuring the actuator relays, you need to calibrate the actuators. Calibrating the actuator lets
the Supra know the position of the actuator when it is fully extended and fully retracted. The Supra
uses the limits to define the range of motion it uses to position the inlets. These limits tell the Supra
how much to adjust when you want the actuators, for example, only 25% extended.
There are two stages to calibrating actuators. Stage 1 is testing the open and close functions and
setting the limit switches. Testing an actuator really means testing the inlets it is controlling. Stage 2
is calibrating the actuator. In the following steps, we assume the actuator is positioning an inlet.
Because cables can stretch and equipment can come out of alignment (similar to
tires on your car), Phason recommends resetting the limit switches and calibrating
your actuators at least once each year.
Zone
Mode
Tunnel option (
yes
is enabled;
no
is not enabled)
Name
_Relay 1 Zone 1
Unassigned
Tunnel turn off? No
Name: Rly 01