background image

PSSW/TX 

INTRODUCTION

  

 

System description 

 

The  PSSW    system  is  designed  for  installation  with  a  safety  edge  in 
powered  door  or  gate  installations.    This  system  allows  for  wireless 
safety edge – control panel connection.  
To install this system, you must follow the advice included in this man-
ual and take the requirements of the applicable normative into account. 
   

Normative requirements 

 

The directives applicable to this system are:   

-        98/37/EC Machines Directive  
-        73/23/EEC Low Voltage Directive  
-        2004/108/EC Electromagnetic Compatibility Directive  
-        R&TTE  1999/5/EC  Radio  and  telecommunication  terminal 

equipment Directive  

Below are some of the requirements of the applicable harmonised 

standards: 

In accordance with the European low voltage directive, you are informed 
of  the  following  requirements: ·  For permanently  connected  equipment, 
an  easily  accessible  connection  device  must  be  incorporated  into  the 
cabling.  ·  This  equipment  must  be  installed  in  a  vertical  position  and 
firmly fixed to the structure of the building. · This equipment may only 
be handled by a specialized installer, by maintenance staff or by a prop-
erly instructed operator. · The instructions for use of this equipment must 
always  remain  in  the  possession  of  the  user.  ·  Terminals  with  a  maxi-
mum section of  3.8mm² must be used to connect the cables.  
               - The frequency of the PSSW  system does not interfere in any 
way with the 868 MHz remote control systems. However a  signal cen-
tred at 868,9MHz may cause a delay on the reaction of the system.  
               - Always connect the powered door or gate structure and metal 
parts to an earthing connection.   
               -Do not share the power and signal supply.  
The PSSW  system is in line with the Machines Directive under EN 954-
1, Category 2.  

Tapeswitch  Limited  declares  herewith  that  the  product  ,  PSSW/TX, 
PSSW/RX, complies with the requirements of the 1999/5/ CEE R&TTE 
Directive,  89/336/EEC  Directive  on  electromagnetic  compatibility  and 
73/23/EEC  on  low  voltage  and  its  subsequent  amendment  93/68/EEC, 
insofar as the product is used correctly. 

 

This  device 

complies  with  Part  15  of  the  FCC  Rules. 

Operation  is 

subject  to  the  following  two  conditions:  (1)  this  device  may  not  cause 
harmful  interference,  and  (2)  this  device  must  accept  any  interference 
received, including interference that may cause undesired operation.  

TECHNICAL FEATURES PSSW/TX RADIO TRANSMITTER 

Operating frequency 

868.90MHz 

Power supply 

3V DC (2 x 1.5V LR6 AA) 

Op. consumption 

12mA 

Radiated power 

< 25mW 

Op. temperature 

-20ºC - +55ºC 

Seal 

IP66 

Dimensions 

160 x 53 x 20mm 

Range (guaranteed) 

10m 

Battery life 

2 years 

Minimum time between two 
or more PSSW/TX activations 
(for complying with the 
R&TTE Directive) 

7 min 

PSSW/TX 

Frequency  

868.90MHz  

Memory  

6 off PSSW/TX (3 on relay 1, 3 on 

relay 2)  

Number of relays  

2 relays  

Power supply  

12/24V AC/DC  

Power supply range  

9-35V DC 8-28V AC  

Relay contacts  

1A  

Consumption: idle/op.  

18mA/80mA  

Self-test input  

2 off 0/12/24V AC/DC inputs with 

selectable polarity   

Power  

< 25mW  

Op. temperature  

-20ºC to +85ºC  

Seal  

IP54 (with IP65 cable seals)  

Box size  

82 x 190 x 40mm  

Range (guaranteed)  

10 metres  

PSSW/RX

 

TECHNICAL FEATURES PSSW/RX RADIO RECEIVER 

INSTALLATION AND CONNECTION 
 
PSSW/TX 

Fix the back of the box to the powered door or gate. Install the transmit-
ter  following  the  technical  manual  and  avoid  placing  metallic  surfaces 
between  the  receiver  and  the  transmitter.  Pass  the  cables  through  the 
bottom  of  the  transmitter.  Connect  a  Tapeswitch  8K2  safety  sensing 
edge directly to terminal B1 and ensure that the safety edge keeps totally 
waterproof.  Fix  the  front  of  the  transmitter  to  the  back  with the  screws 
supplied for the purpose.  

Operation 

The receiver checks that all the programmed sensing edges are working 
properly. If a sensing edge is activated or if there is an error in its opera-
tion, the receiver activates the output relay.   

Programming the PSSW/TX  

If  the  receiver  is  in  programming  mode  (see  MANUAL  PROGRAM-
MING ), press the programming button on the transmitter to program it 
into the receiver.  

Transmitter battery low indicator (PSSW/TX)  

If  the  battery  of  a  transmitter  programmed  into  the  receiver  becomes 
low,  it  will  give  out  4  short  signals  every  20  seconds.  If  there  is  more 
than one transmitter programmed, the safety sensing edge must be acti-
vated to check whether the receiver then makes these 4 short signals. If 
this is the case, the transmitter connected to the activated safety sensing 
edge  will  be  the  one  with  the  low  battery.  Both  batteries  must  be 
changed.   

Changing the battery  

Remove  the  box  cover.  The  batteries  are  positioned  on  the  back  of  the 
cover. Replace the two used batteries with new ones, taking into account 
the polarity  indicated by  the  connector. 

Check  that  the  new  batteries 

support the same temperature range as those they are replacing.  
 

PSSW/RX 

Fix the back of the box to the wall, using the wall plugs and screws sup-
plied.  

Install  the  receiver,  close  to  the  powered  door  or  gate  and  avoid 
metal  surfaces  between  the  receiver  and  the  transmitter.

  Pass  the 

cables  through  the  bottom  of  the  receiver.  Connect the  power  cables  to 
the terminals of the printed circuit, following the indications of the con-
nections  diagram.    Fix  the  front  of  the  receiver  to  the  back  with  the 
screws supplied for the purpose.  

 
Connections 

1-      Power supply 12/24V AC/DC: (+)  
2-      Power supply 12/24V AC/DC (-)  
3,4- Output R1: The PSSW/RX can present two types 

of output to the powered door or gate control 
panel to indicate that the sensing edge is not acti-
vated.  If the jumper on the PSSW/RX is in posi-
tion CS1 a closed contact will be present between 
connections 3 and 4 when the sensing edges pro-
grammed to that output are all clear.  This contact 
will open if any sensing edge is activated or fails 
thee auto test.  If the jumper is in position BS1, a 
resistance of 8K2 will be present between connec-
tions 3 and 4 when the sensing edges programmed 
to that output are all clear.  This connection will 
be open-circuit if any sensing edge programmed 
to this output is activated or fails to auto test. 

5,6- Output R2: As above but using jumper positions 

CS2 or BS2 

7- COM: Common connection safety self test (-). See 

AUTOTEST FUNCTION 

8- ATEST1: Self-test connection for Output R1 

AUTOTEST FUNCTION 

9- ATEST2: Self-test connection for Output R2. 

AUTOTEST FUNCTION.  

PSSW /RX  

In operation  

In programming  

Relay 1 LED  

Normally off. Indi-
cates the status of the 
relay output. If R1 is 
not connected, on.  

On. Indicates the 
channel to be pro-
grammed.  

Relay 2 LED  

Normally off. Indi-
cates the status of the 
relay output. If R2 is 
not connected, on.  

On. Indicates the 
channel to be pro-
grammed.  

OPERATION  

 
The receiver checks that all the programmed sensing edges are working 
properly. If a sensing edge is activated or if there is an error in its opera-
tion, the receiver activates the output relay.   
 

MANUAL PROGRAMMING 

 

PSSW/RX makes it possible to store 6 s and/or PSSW/TXs (3 on Relay 
1 and  3  on  Relay  2).  Press  the  receiver  programming  PROG  button  for 
one second; a sound signal will be heard. The receiver will go into pro-
gramming the first relay. If the programming button is kept pressed, the 
receiver  will  go  into  programming  the  second  relay,  moving  cyclically 
from one relay to another. Once the programming relay has been chosen 
for  the  transmitter  you  want  to  start using,  send  the  programming  code 
by pressing the transmitter programming button. Every time a transmit-
ter  is  programmed, the  receiver  will  emit  a  sound  signal  for  0.5s.  If  10 
seconds pass without programming, the receiver will go out of program-
ming  mode,  emitting  two  1s  sound  signals.  If,  when  programming  a 
transmitter,  the  receiver's  memory  is  full,  it  will  emit  7  sound  signals 
lasting 0.5s and come out of programming.  

Note:  For  correct  operation  of  the  system,  a  transmitter  has  to  be 
programmed in one receiver only. 

 

PSSW/TX  replacement:

 In case you need to replace a  PSSW/TX, it is 

necessary  to  reset  the  system  (see  TOTAL  RESET  on  next  page)  and 
reprogram all PSSW/TXs used in the installation.  
 

SYSTEM CHECK 

 

This function has to be used to check the operation and range of all the 
devices once the installation has been carried out.   
Press the receiver’s CHECK button for at least 1 second to enter check 
mode.  The  indicator  light  will  come  on  and  four  beeps  will  be  heard.  
Perform a complete powered door or gate opening and closing manoeu-
vre.  During the system check a beep will be heard every 1,5 seconds.  

C

orrect operation of the system  

If  no  other  acoustic  signal  is  heard  on  completing  the  manoeuvre,  the 
system  is  operating  correctly.  Either  press  the  CHECK  button  again  or 
wait 5 minutes and the PSSW/RX will exit checking automatically, indi-
cating with two beeps that the check has been correct. The check indica-
tor light will go out.  

Detection of sensing edge failure 

 

If  the  communication  with  a  PSSW/TX  fails  during  checking,  or  the 
communication  is  deficient  (for  instance,  too  many  communication  re-
tries  or  poor  coverage),  the  PSSW/RX  emits  three  consecutive  beeps, 
indicating that an error has occurred. Halt the powered door or gate ma-
noeuvre  and  press  the  safety  sensing  edge  installed  to  detect  what  has 
failed.   
               -              If  a  single  beep  is  heard  on  pressing  a  sensing  edge, 
this means that the sensing edge is correct.  

-          If  three  consecutive  beeps  are  heard  on  pressing  the 

sensing edge, this means that the sensing edge has failed.  In this event, 
it is recommended changing the orientation of the transmitting-receiving 
aerials or installing a powered aerial to ensure the desired range.  

 

On  exiting  check  mode,  seven  consecutive  beeps  will  be  heard  and  the  
i n d i c a t o r  

l i g h t  

w i l l  

f l a s h  

c o n t i n u o u s l y .  

Perform another system check until the result is correct.  
 

SIGNAL COVERAGE 

 

After  pressing  one  of  the  installed  sensing  edges,  continuous  flashes, 
ranging from 1 to 5, indicate the signal coverage for this band at the time 

Number of check 

LED flashes  

Coverage  

Result of check  

1  

Very weak  

Safety edge failure  

2  

Weak  

OK  

3  

Normal  

OK  

4  

Good  

OK  

5  

Very good  

OK  

TOTAL RESET 

 

In programming mode, keep the programming PROG button pressed 
down and make a bridge with the "MR" reset jumper for 3s. The re-
ceiver will emit 10 warning sound signals and then more at a faster 
frequency, indicating that the operation has been carried out. The 
receiver will stay in programming mode. If 10 seconds elapse without 
programming, or if you press the programming button quickly, the 
receiver will go out of programming mode, emitting two 1s sound 
signals.  

Sensing edge 

Programming button 

      

Selector Bridge R1

 

      

Selector Bridge R2

 

      

Relay-activated Indicator Lights 

      

Programming Button 

      

Total Reset Bridge MR

 

      

Check Button and LED

 

 

PSSW/RX 

 

Tapeswitch Ltd 

Unit 38 Drumhead Road  
Chorley North Ind Park 
Chorley 
Lancs 
PR6 7BX 
United Kingdom 
 
Tel                   0044 1257 249777 
Fax                  0044 1257 246600 
E-mail             [email protected] 

PSSW Wireless safety-edge controller 
343192—Technical Manual 

Отзывы: