background image

AUTO-TEST DESCRIPTION 

 

Before starting operations, the gate/door control panel must check that the entire safety system is working cor-
rectly.  

PSSW / TX

PSSW / RX

GATE

CONTROL

APPLY

TEST

TEST

OUTPUT

GATE CONTROL CABINET

FAIL

TEST

STOP GATE

& LOCKOUT

MOTION

TAPESWITCH

SENSING EDGE

T

E

S

T

O

U

T

P

U

T

In order to comply with Type 2 of safety standard EN12453 (the safety standard for the use of powered doors), 
an automatic test of the output(s) of the PSSW should be applied and checked by the gate/door control unit be-
fore every operation. If the outputs fail to respond, the operation of the gate/door should be prevented until the 
situation  is  corrected.  The  auto-test  can  be  applied  by  a  signal  connected  to  ATEST1  (for  output  R1)  and/or 
ATEST2 for (output R2). Only apply the auto-test for outputs that are being used. . The PSSW/RX can deal with 
positive- or negative-polarity auto-test signals applied by the gate control cabinet. 

 

Auto-test out-
put in standby  

Auto-test out-
put activated  

Polarity type   Jumper AT-

EST POL  

ATEST1  

ATEST2  

Connection to 
equipment 
with autotest 

0V  

12/24V  

Positive  

OFF  

Connected  

Connected  

 

12/24V 

0V 

Negative 

ON 

Connected 

Connected 

Connection to 
equipment 
without 
autotest 

 

 

 

OFF  

Not connected  Not connected 

With no  jumper  in  the  ATEST  POL  position,  the  applied  auto-test  signal  should normally  be  at  0V and  go to 
+12/24V for at least 2s before returning to 0V. With a jumper in the ATEST POL position, the applied auto-test 
signal should normally be at +12/24V and go to 0V for at least 2s before returning to +12/24V. The COM con-
nection  for  ATEST1  and  ATEST2  (pin  7)  must  be  connected  to  the  common  of  the  control  unit  applying  the 
auto-test.  
 
Applying the auto-test signal should cause the relevant output to change state and this should be checked.  
 
With no jumper in ATEST POL and no auto-test signal applied, EN12453 will not be fully complied with. 

*N.B.: Only connect the auto-test output to be used.  

** Where the auto-test is not used, the system is not checked at the start of the operation, which means 
that  safety  standard  EN  12453  regarding  the  use  of  a  powered  door  or  gate,  is  in  some  cases,  not 
complied with.

 

INSTALLATION ADVICE 

 

Install the equipment so that the cable 
gland is at the bottom. In installations that 
could possibly have range problems be-
tween the transmitter and receiver, ensure 
that the antenna hangs vertically from the 
hole in the cable gland. 

Do not fit the equipment at ground level. 

Do not place metal surfaces between the 
transmitter and the receiver 

The transmitter and receiver antennae must be parallel 
to each other for optimum signal reception 

Once the system has been installed, check that it works correctly by enabling the 
safety edge on the ends of the powered gate. 

 

Tapeswitch Ltd 

Unit 38 Drumhead Road  
Chorley North Ind Park 
Chorley 
Lancs 
PR6 7BX 
United Kingdom 
 
Tel                  0044 1257 249777 
Fax                 0044 1257 246600 
E-mail             [email protected] 

Installation on horizontal sectional powered door or gate with control panel and PSSW/RX 

Installation on roller powered door or gate with control panel and PSSW/RX. 

 

Installation on one-leafed sliding powered door or gate with control panel and PSSW/RX. 

 

Отзывы: