LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 233 of 463
Query Format
PROGram[:SELected]:SST? [,<nr1>] [,<cr>]
Description
This command returns the
S
teady
S
tate
T
able settings of the selected
program only. The transient table data is not returned.
Parameters
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Returned Data Format
<cr>
Query Example
PROG:SST? 2, USB
-> steady state table program data
Query Format
PROGram:EXECuted:SST? [,<nr1>] [,<cr>]
Description
This command returns the
S
teady
S
tate
T
able settings of the
executing program only. The transient table data is not returned.
Parameters
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Returned Data Format
<cr>
Query Example
PROG:EXEC:SST?
-> steady state table program data
Query Format
PROGram[:SELected]:TT? [,<nr1>] [,<cr>]
Description
This command returns the
T
ransient
T
able settings of the selected
program only. The steady state table data is not returned.
Parameters
Option: STYLE [,<nr1]
0 = Human readable Style A (default if omitted)
1 = Human readable Style B
2 = Binary Data Format. Can be more useful to search for differences
between programs.
See
PROGram:TT?
Command for formats
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Returned Data Format
<cr>
Query Example
PROG:TT? 1
-> transient table program data