LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 254 of 463
8.7.3
Frequency Programming Commands
Command Syntax
[SOURce:]FREQuency
Description
Sets output frequency for all phases.
Parameters
15.00 – 5000.0
Range is adjust on models with T Option
Parameter Format
<nr2>
Example
FREQ 400.0
Query Format
[SOURce:]FREQuency?
Returned Data Format
<nr2>
Query Example
FREQ?
400.0000
Command Syntax
[SOURce:]FREQuency:LIMit:MINimum
Description
Sets the lower user limit for frequency programming. Not that the
lower limit set value must be less than the upper limit set value or an
error will be generated and no change to the set value will take place.
The lower limit set value must fall within the source specified
frequency range capability.
Parameters
15.00 – 5000.0
Range is adjust on models with T Option
Parameter Format
<nr2>
Example
FREQ:LIM:MIN 47.0
Query Format
[SOURce:]FREQuency:LIMit:MINimum?
Returned Data Format
<nr2>
Query Example
FREQ:LIM:MIN?
47.0000
Command Syntax
[SOURce:]FREQuency:LIMit:MAXimum
Description
Sets the upper user limit for frequency programming. Note that the
upper limit set value must be greater than the lower limit set value or
an error will be generated and no change to the set value will take
place. The upper limit set value must fall within the source specified
frequency range capability.
Parameters
15.00 – 5000.0
Range is adjust on models with T Option
Parameter Format
<nr2>
Example
FREQ:LIM:MAX 63.0
Query Format
[SOURce:]FREQuency:LIMit:MAXimum?
Returned Data Format
<nr2>
Query Example
FREQ:LIM:MAX?
63.0000