LMX Series Power Source Operation Manual
Page 139 of 463
of the installed output transformers.
Note:
In either coupled mode, only
AC
voltage
programming is possible.
Access to other utility screens is available from the UNIT CONFIGURATION screen through
the soft keys. The table below lists the available soft keys on the UNIT CONFIGURATION
screen.
SOFT KEY
Description
User Limits (SK1)
Displays SETUP MENU screen. Refer to section 0
Ramp & Slew (SK3)
Displays SLEW RATE MENU screen. Refer to section 6.7.3
Program Memory (SK2)
Displays PROGRAM MEMORY screen. Refer to section 0
CSC Config. (SK4)
Display CSC setting screen
Next Screen (SK5)
Toggle to alternate UNIT CONFIGURATION screen
Table 6-20: Available UNIT CONFIGURATION 1 screen soft keys
UNIT CONFIGURATION 2 OF 2 ----------------------------------------------------------------------------------
Allow Output Enable at Power On
This mode if set, causes the output to turn on at
power up.
Enable Current Overload
Current Overload mode allows the power source to provide
more than the nominal max. RMS current (around 30
percent more) for a short period (up to 2 seconds). When
enabled, the user can set the CURR:LIM 30% higher than
whit this mode off. For example in a stand-alone 360LMX
unit in three phase mode (FORM 3), RMS output current
can be up to 55A when the continuous output limit is 16A.
A warning message will be displayed notifying the user this
mode is being enabled.