LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 296 of 463
Command Syntax
[SOURce:]STEP:LOAD
Description
This command converts the step transient definition to the power
source’s regular transient segment format and loads it in the
controller real-time memory for execution.
Parameters
None
Parameter Format
n/a
Example
STEP RUN
Query Format
[SOURce:]STEP:LOAD?
Description
Query format returns a 1 if the step transient load operation was
successful, otherwise returns 0.
Returned Data Format
<nr1>
Return values respresent:
0
Load Failed
1
Load completed
Query Example
STEP?
1
Query Syntax
[SOURce:]STEP:PROGress?
>>> Alias for PROGram:TRANsient:PROGress command. <<<
Description
This query command returns the status of the step being executed.
Parameters
None
Parameter Format
n/a
Description
Query returns the step transient execution state as either RUN, STOP,
PAUS, STEP or REST
Returned Data Format
<cr>
The response is a comma-separated value string representing:
PROGRESS, CURRENT SEGMENT PROGRESS, CURRENT SEGMENT, CURRENT
SEGMENT TIME, TOTAL TIME, TOTAL SEGMENTS, REPEAT TIME COUNTER
Query Example
STEP:PROG?
1, 45, 2, 1.2300, 2.0000, 4, 5
Query Syntax
[SOURce:]STEP:CHECK?
Description
This query command returns the result of a check on the
programmined step parameters to determine if they are ok to run.
Parameters
None
Parameter Format
n/a
Description
Query returns result of STEP parameters integrity check
Returned Data Format
<cr>
The response is either OK or if not, a string containing the error.
Query Example
STEP:PROG?
OK