LMX SERIES™ OPERATION MANUAL
SECTION 7: Auxiliary I/O
Error! Reference source not found.
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 200 of 463
7.12.7
External Sync
External sync is used to synchronize the power source’s phase A output to an external
frequency.
Available settings are:
•
STATUS
Display SYNC Status
•
EXTERNAL SYNC
[ ON | OFF ]
•
SYNC SOURCE
Select Sync source
•
Available sync sources are:
- External sync input on I/O connector
- LINE (AC input to power source)
•
PHASE SHIFT
Offset Phase A angle
•
SPEED
1.00 to 10.00
•
RANGE
0.10 to 5000 Hz
•
EXTERNAL SYNC
[ ON | OFF ]
7.12.8
Trigger Input
The External Trigger Input can be used to synchronize the power source’s transient
execution to external equipment. This
Available settings are: