LMX SERIES™ OPERATION MANUAL
SECTION 12: Warnings & Error Messages
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 440 of 463
Error Source
Code
Category Error Message
Possible Cause
Resolution
Front panel
37
Error
Interface response packet
out of space.
Front panel
42
Error
Memory in use was
removed.
Front panel
47
Error
Front panel is shutting
down.
Front panel
48
Error
Fault state cannot be
automatically reset.
Front panel
51
Error
The command cannot be
executed in auxiliary unit.
Front panel
53
Error
Error during firmware
update.
Firmware Update Error.
Update may have failed
Check for correct
firmware image file and
version.
Front panel
54
Error
Calibration coefficient
cannot be negative.
Negative Calibration
Coefficients are not
allowed
Make sure cal coefficients
are positive values
Front panel
56
Error
Waveform name is not
available.
Waveform name
requested does not exist
Use existing waveform
name from waveform
library
Front panel
57
Error
Waveform file is not
available.
Waveform register
selected is empty
Download valid
waveform data to
selected register
Front panel
58
Error
Waveforms lengths are
different between
controllers.
Waveforms lengths are
not equal between three
phases
Check waveform data for
correct length
Front panel
59
Error
Unit does not exist.
Unit selected cannot be
found
Try recycling power. If
error persists, contact
customer service
Front panel
60
Error
Cannot read ambient
temperature
Front panel
64
Error
Unexpected reset.
Inverter controllers were
reset
Try recycling power. If
error persists, contact
customer service
Front panel
65
Error
Front panel is in passive
mode.
Passive Mode. Front
panel is most likely an
auxiliary unit
Check parallel
configuration
Front panel
66
Error
Invalid host name.
Host name requested is
invalid
Try recycling power. If
error persists, contact
customer service
Front panel
67
Error
DC voltage set point
cannot change due to
waveform saturation.
Setting conflict.
Waveform data and DC
setting or in conflict
Adjust DC setting or
waveform to resolve
conflict
Front panel
68
Error
AC voltage set point
cannot change due to
waveform saturation.
Setting conflict.
Waveform data and AC
setting or in conflict
Adjust AC setting or
waveform to resolve
conflict
Front panel
69
Error
Maximum user limit is
lower than set point.
Setting conflict. Set point
exceeds upper user limit
Adjust setting or user
limit
Front panel
70
Error
Minimum user limit is
higher than set point.
Setting conflict. Set point
is below lower user limit
Adjust setting or user
limit
Front panel
72
Error
Minimum limit is higher
than maximum.
Setting conflict. Max.
User Limit must be higher
than Min. User Limit
Adjust User Limits
Front panel
73
Error
Maximum limit is lower
than minimum.
Setting conflict. Max.
User Limit must be higher
than Min. User Limit
Adjust User Limits