manualshive.com logo in svg
background image

 

1

 

www.fiduspower.com

  

 

MVPS600 

Series

  

 

Model Number 

(1)  

 

Output Power

(2)  

 

Output Voltage 

 

Output Current (Natural Convection)        

 

U Channel

 

Slotted Cover

 

Solid Cover

 

MVPS600

-

1

0

12

 

180

-

300W

 

12V

 

25A

 

17.5A

 

15A

 

MVPS600

-

1

0

15

 

225

-

375W

 

15V

 

25A

 

17.5A

 

15A

 

MVPS600

-

1

0

24

 

360

-

600W

 

24V

 

25A

 

17.5A

 

15A

 

MVPS600

-

1

0

30

 

360

-

600W

 

30V

 

20A

 

14A

 

12A

 

MVPS600

-

1

0

48

 

360

-

600W

 

48V

 

12.5A

 

8.75A

 

7.5A

 

MVPS600

-

1

0

58

 

360

-

600W

 

58V

 

10.34A

 

7.25A

 

6.2A

 

Models & Ratings

 

Dimensions:

 

5 x 8.5 x 

1.61” (127 

x 216 x 40.9mm)

 

Parameter

 

Minimum

 

Typical

 

Maximum

 

Units

 

Notes & Conditions

 

AC Input range

 

85

 

 

264

 

VAC

 

Derate from 100% at 120VAC to 70% at 85VAC

 

Operating temperature

 

-

40

 

 

70

 

°C

 

See derating curve p3. 

 

Efficiency

 

120VAC 88% and 240VAC 93% typical

 

Dimensions

 

5 x 8.5 x 

1.61” (127 

x 216 x 40.9mm)

 

EMC

 

EN55011 Level B conducted and radiated with king core K5B RC 25x12x15

-

M on input.  EN61000

-

3 and EN61000

-

4, harmonics, 

flicker, Surge, EFT, ESD, conducted and radiated immunity to IEC 60601

-

1

-

2 4th ed

 

Safety

 

EN60601

-

1, IEC60601

-

1 (ed3), ANSI/AMMI ES 60601

-

1, CSA C22.2 No 60601

-

1

 

Key specifications

 

• 

5 x 

8.5” 

Footprint, 

1.61” 

for 1U installation 

 

• 

Latest medical approvals IEC60601

-

1 (3.1) IEC60601

-

1

-

2 (4th ed), BF rated

 

• 

Up to 3 units load share for higher powers 

 

• 

Peak of 1000W for 500mS

 

• 

EN55011 Level B conducted & radiated

 

• 

5 Year warranty

 

 

600 Watts

 

The MVPS600 series of low profile, medically approved AC

-

DC power modules offer 300

-

600W in a 

5” 

8.5” 

package conforming to the latest IEC60601

-

1 3.1 and IEC60601

-

1

-

2 4th ed standards. The 

units are fully featured including 5V 1.5A auxiliary output and low standby power of 3W. The units are 
body floating (BF) rated for applied part applications. They have a wide operating temperature of –

40 

to 70°C, in a range of voltages from 12V to 58V. All units come with a FiDUS 5 year warranty.

 

Notes  

 

INSTALLATION ADVICE PG6

 

2.  Combined output power is main DC  fan output 12V / 500mA max

 

1.  For sotted cover change 

above for 

S

, for sold cover version change 

0

 above for 

T

 

3.  1000W overload for 500mS for 30V 48V and 58V only, not field configurable.

 

Содержание MVPS600 Series

Страница 1: ...y to IEC 60601 1 2 4th ed Safety EN60601 1 IEC60601 1 ed3 ANSI AMMI ES 60601 1 CSA C22 2 No 60601 1 Key specifications 5 x 8 5 Footprint 1 61 for 1U installation Latest medical approvals IEC60601 1 3 1 IEC60601 1 2 4th ed BF rated Up to 3 units load share for higher powers Peak of 1000W for 500mS EN55011 Level B conducted radiated 5 Year warranty 600 Watts The MVPS600 series of low profile medical...

Страница 2: ...al Isolation Input to Output 4245 VAC Input to Ground 1625 VAC Output to ground 1500 VAC Switching frequency 85 100 kHz 100 kHz variable for power switching Variable PFC switching 85kHz Power density 8 77 W In3 MTBF 1 28 MHrs As per Telcordia SR332 issue 3 Weight 1100 g General Parameter Minimum Typical Maximum Units Notes Conditions Operating temperature 40 70 C Please see derating curve on page ...

Страница 3: ...4 11 100 for 0 5 1 cycle 30 for 25 cycles B B B interrupt 250 300 cycles and 30 for 30 cycles B B B EMC Immunity Safety standard Notes Conditions UL CSA ANSI AMMI ES 60601 1 CSA C22 2 NO 60601 1 UL Certificate No 20190221 E173812 CB IEC60601 1 3rd ed CB Test Certificate No NO105338 Nemko EN60601 1 3rd ed Nemko Certificate No P19223365 CE 2015 863 EU RoHS Directive and 2014 35 EU Low voltage direct...

Страница 4: ...ction When using the load share function derate the cumulative power total by 10 Please follow the below step by step process to ensure smooth operation Connect all output cables to Vout Connect all Vs cables and twist pairs together Terminate all the Vs lines to the same points Connect the load share LS pin 10 on J3 of all the units With other units tuned off on each PSU use the output adjust to ...

Страница 5: ...Can accept AMP 8 31886 1 Tongue 11A max AWG16 J3 I O Connector 4 Pin Connections Pin Function 1 GND 2 5V 1 5A 3 PGPF 4 VS 5 VS 6 GND 7 Remote on off 8 Current limit p2 9 Current limit p1 10 Load share ULP275 Series WLP350 Series 4 J3 I O header Molex 22 23 2101 mating part Molex 22 01 2107 MVPS600 Series J1 Input Connector 2 Pin Connections Pin Function 1 Line 2 Neutral 3 Earth U Channel Slotted c...

Страница 6: ...s but on some power supplies there may be additional earth tags or mounting points 2 Minimise the length of input output wiring where possible and try to maintain max distance of the conductors from the PSU to prevent noise pick up Avoid bundling input and output cables together A common component to avoid placing wiring near is the PFC inductor in power factor corrected power supplies 3 Apply add...