LMX SERIES™ OPERATION MANUAL
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 140 of 463
Recall last settings at power-on
When checked, this mode will cause the last settings that
were in effect when the power source was last turned off to
be recalled at power on. This allows a user to resume
operation without having to set up again between power
on/off events.
Positive phase rotation
When checked, the phase rotation in three phase mode will
be set to A -> C -> B corresponding to positive phase
rotation for three phase AC motors. To select negative
phase rotation, uncheck this option.
Invert polarity in split phase
When checked, the AC waveform in split-phase mode of
operation is shifted 180° (inverted).
Output disable zero program
When checked, the programmed voltage is first set to zero
voltage when pressing the Output Enable button or
executing the OUTP OFF command. This allows any energy
stored in the EUT to dissipate into the low impedance
output of the power source before the relay disconnects the
load.
Access to other utility screens is available from the UNIT CONFIGURATION screen through
the soft keys. The table below lists the available soft keys on the UNIT CONFIGURATION
screen.
SOFT KEY
Description
Transient Settings (SK1)
Display Transient Configuration Settings
Output Impedance (SK2)
Program Output Impedance R and L values.
User Presets (SK3)
Access to user defined preset value settings for output
programming soft keys
Next Screen (SK5)
Toggle to alternate UNIT CONFIGURATION screen
Table 6-21: Available UNIT CONFIGURATION 2 screen soft keys