LMX SERIES® OPERATION MANUAL
SECTION 4: Technical Specifications
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 43 of 463
Waveform Capture
Time Domain
1024 samples/period
Parameters
V
LN
-A, V
LN
-B, V
LN
-C, V
LL AB
,V
LL AC
,V
LL BC ,
IA, IB, IC
Samples/cycle
1024 (512 in UPC Compatibility mode)
Record Length
1 Period of fundamental Frequency
Bandwidth
100 kHz @ 500 ksps
Harmonics Measurements
Parameters
V
LN
-A, V
LN
-B, V
LN
-C, V
LL AB
,V
LL AC
,V
LL BC ,
IA, IB, IC
Harmonics Range
H1 ~ H50
Accuracy – Amplitude
± 1.0 % of RMS Reading
Phase Angle Range
0 ~ 359.9
Accuracy - Phase Angle
< 8
µ
sec
Bandwidth
100 kHz @ 500 ksps
Display Modes
Table format, Graph Format
4.9
Transients
Transients
Programming
No. of Entries
200 Steps, 400 Segments
Parameters
Voltage, Frequency, Phase B &C, Ramp Time, Dwell Time
Dwell Time Range
0.1 – 10,000,000.0 msec
Ramp Time Range
0.1 – 10,000,000.0 msec
Time Resolution
100
µ
sec (0.0001 sec)
Edit Modes
Add at End, Insert Before, Delete
Execution
Run Control
Run from Step # to Step #
Run, Step, Restart, Stop
Program Storage
Non-Volatile
100, Pr Transients