LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 276 of 463
Query Syntax
[SOURce:]PROTect[:RMS]:KVA:LEVel:MAXimum?
Description
This command returns the maximum apparent power protection
level setting.
Query Example
PROT:KVA:LEV:MAX?
41.667
Query Syntax
[SOURce:]PROTect[:RMS]:KVA:LEVel:DEFault?
Description
This command returns the default apparent power protection level
setting. This value will be a function of the power source model.
Query Example
PROT:KVA:LEV:DEF?
41.667
Command Syntax
[SOURce:]PROTect[:RMS]:KVA:TDELAY <DELAY>
Description
This command sets the apparent power protection trip delay time.
Setting is in multiples of 100 msec so 5 equals 500 msec.
Parameters
< LEVEL >
Parameter Format
<nr2>
Example
PROT:KVA:LEV 5
Query Format
[SOURce:]PROTect[:RMS]:KVA:TDELAY?
Returned Data Format
<b>
Query Example
PROT:KVA:TDELAY?
5.000
Query Syntax
[SOURce:]PROTect[:RMS]:KVA:TDELAY:MINimum?
Description
This command returns the minimum apparent power protection trip
delay time setting.
Query Example
PROT:KVA: TDELAY:MIN?
0
Query Syntax
[SOURce:]PROTect[:RMS]:KVA:TDELAY:MAXimum?
Description
This command returns the maximum apparent power protection trip
delay time setting.
Query Example
PROT:KVA: TDELAY:MAX?
3000
Query Syntax
[SOURce:]PROTect[:RMS]:KVA:TDELAY:DEFault?
Description
This command returns the default apparent power protection trip
delay time setting.
Query Example
PROT:KVA:TDELAY:DEF?
5
Query Syntax
[SOURce:]PROTect[:RMS]:KVA:TRIPped?
Description
This command returns the apparent power protection trip status.
Returns 1 if tripped or 0 if not.
Query Example
PROT:KVA:TRIP?
41.667