LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 326 of 463
8.9.6
System Sanitization Commands
Query Format
SYSTem:SANITIZE:CODE?
Description
Returns sanitization password string.
Returned Data Format
<nr1>
Query Example
SYSTem:SANITIZE:CODE?
0659
Command Syntax
SYSTem:SANITIZE <code>
Description
Erases all user data stored in non-volatile memory settings including
settings and custom waveforms if required. The code is obtained by
the query command above.
Parameters
None
Parameter Format
n/a
Example
SYST:SANITIZE 0659
8.9.7
Communication LAN Commands
Command Syntax
SYSTem:COMMunicate:LAN[:ENABle]
Description
This command turns remote control via LAN on or off. To control the
power source through its LAN interface, this state has to on (1).
Parameters
< 0 | OFF | 1 ON >
Parameter Format
<b>
Example
SYST:COMM:LAN ON
Query Format
SYSTem:COMMunicate:LAN[:ENABle]?
Returned Data Format
Query Example
SYST:COMM:LAN?
1
Query Format
SYSTem:COMMunicate:LAN:STATus?
Description
This command returns all LAN settings in a single comma delimited
string of values.
Returned Data Format
<cr>, <cr>,…..,<cr>,<cr>
Query Example
SYSTem:COMMunicate:LAN:STATus?
192.168.14.22,255.255.254.0,192.168.15.254,192.168.15.208,LMX-
106378937,LMX-106378889,0,1,0