8.9.10
Communication GPIB Commands
Command Syntax
SYSTem:COMMunicate:GPIB:ADDress <nr1>
Description
This command sets the GPIB address.
Parameters
< 1..30 >
Parameter Format
<nr1>
Example
SYST:COMM:GPIB:ADD 5
Query Format
SYSTem:COMMunicate:GPIB:ADDress?
Returned Data Format
<nr1>
Query Example
SYST:COMM:GPIB:ADD?
5
Command Syntax
SYSTem:COMMunicate:GPIB:ENABle
Description
Enables access to embedded webserver using virtual IP Address
through USB interface.
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
SYST:COMM:GPIB:EANB 1
Query Format
SYSTem:COMMunicate:GPIB:ENABle?
Returned Data Format
<b>
Query Example
SYST:COMM:GPIB:ENAB?
1
Command Syntax
SYSTem:COMMunicate:GPIB:BAUDrate
Description
Sets the internal serial link speed between the GPIB interface and the
front panel processor. This setting is set to 921600 bps as a default
and should only be changed to a lower setting if there is a problem
with the GPIB interface not working reliably.
Parameters
< 1200 | 1800 | 2400 | 4800 | 9600 | 14400 | 19200 | 38400 | 57600 |
62500 | 115200 |230400 | 460800 |500000 | 576000 | 921600 >
Parameter Format
<nr1>
Example
SYST:COMM:GPIB:BAUD 921600
Query Format
SYSTem:COMMunicate:GPIB:BAUDrate
?
Returned Data Format
<nr1>
Query Example
SYST:COMM:GPIB:BAUD?
921600