6.5.4
Measurement Screen Soft Keys
The following five soft keys are available on the three-phase measurement screen.
SOFT KEY
Description
Datalogger
(SK1)
The Datalogger soft key allows setting the measurement data
logging memory type to be selected, sample rate and no. of
samples to be logged to memory. To use a usb memory stick
(32GB max), insert it in one of the two USB ports on the front
panel and select either USBA1 or USBA2. Only memory devices
found will be selectable in addition to the default internal RAM
(non volatile) memory.
Real Time Plot
(SK2)
Display strip chart of voltage, current or both against time. This
provides a trend plot of any available measured parameter.
The following soft keys are available to control the time plot:
Start
Starts time plot.
Select Meas.
Select parameters to display
Zoom or Scroll
Zoom both X and Y axis
Save
Saves plot data to memory device
Auto Scale
Auto-scale the Y axis (Amplitude)