LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 258 of 463
Command Syntax
[SOURce:]IPEAK:PROTect:STATe
Description
This command enables or disables the user programmable current
protection mode.
Parameters
[ 0 | OFF | 1 | ON ]
Parameter Format
<b>
Example
IPEAK:PROT:STAT 1
Query Format
[SOURce:]IPEAK:PROTect:STATe?
Returned Data Format
<nr1>
Query Example
IPEAK:PROT:STAT?
1
Command Syntax
[SOURce:]IPEAK:PROTect:LEVel
Description
This command sets user programmable the peak current protection
mode level.
Parameters
0.0000 – 100000.0000
Parameter Format
<nr2>
Example
IPEAK:LIM 50.0
Query Format
[SOURce:]IPEAK:PROTect:LEVel?
Returned Data Format
<nr2>
Query Example
IPEAK:PROT:LEV?
50.000
8.7.5
Phase Programming Commands
Command Syntax
[SOURce:]PHASe#
Description
This command programs the phase angle for the selected phase. A
phase reference (#) must be specified.
Note
that unless external sync mode is used, the A phase (# = 1)
cannot be programmed is fixed at 0 degrees.
Parameters
0.0 – 359.9
Parameter Format
<nr2>
Example
PHAS2 122.5
Query Format
[SOURce:]PHASe#?
Returned Data Format
<nr2>
Query Example
PHAS2?
122.5