8.10.4
Analog Input Commands
These commands control the use of analog input signals to drive the output of the LMX
power source. These functions are comparable to those of the legacy AMX Series power
sources.
[SOURce:]ANalog:PROGramming#
[:MODE] [ 0 | OFF | 1 | AMP | 2 | AM | 3 | ADD ]
[:MODE]?
[:AMP]
Applies to AMP and ADD modes
:OFFset
:DEFault?
:MAXimum?
:MINimum?
:OFFset?
:AM
Applies to AM mode
:GAIN
:DEFault?
:MAXimum?
:MINimum?
:GAIN?
:HPF
:STATe
:STATe?
:FREQuency
:DEFault?
:MAXimum?
:MINimum?
:FREQuency?
8.10.4.1
Analog Input Mode Commands
Change between off, amplifier mode, AM or addition to internal waveform.
Available modes:
Value
Mode
0 | OFF
Input disabled
1 | AMP
Amplifier Mode
2 | AM
Amplitude Modulation mode
3 | ADD
Addition or Summing mode
[SOURce:]ANalog:PROGramming#[:MODE] 0,1,2,3/OFF,AMP,AM,ADD
[SOURce:]ANalog:PROGramming#[:MODE]?