Query Syntax
[SOURce:]PULSe:VOLTage[:AC]#:MAXimum?
Description
This command returns the maximum permissible set value for the
PULSE voltage for selected phase # or for all phases if phase
reference is omitted
Returned Data Format
<nr2>
Query Example
PULS:VOLT:MAX?
300.0000
Query Syntax
[SOURce:]PULSe:VOLTage[:AC]#:DEFault?
Description
This command returns the default set value for the PULSE voltage for
selected phase # or for all phases if phase reference is omitted
Returned Data Format
<nr2>
Query Example
PULS:VOLT:DEF?
0.000,0.000,0.000
PULE:VOLT1:DEF?
0.000
Command Syntax
[SOURce:]PULSe:FREQuency < nr2 >, <cr>
Description
This command sets the PULSE frequency.
Parameters
Voltage , < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
Parameter Format
<nr2>, <cr>
Example
PULS:FREQ 50.00
Query Format
[SOURce:]PULSe:FREQuency?
Returned Data Format
<nr2>
Query Example
PULS:FREQ?
60.0000
Query Syntax
[SOURce:]PULSe:FREQuency:MINimum?
Description
This command returns the minimum permissible set value for the
PULSE frequency.
Returned Data Format
<nr2>
Query Example
PULS:FREQ:MIN?
15.0000
Query Syntax
[SOURce:]PULSe:FREQuency:MAXimum?
Description
This command returns the maximum permissible set value for the
PULSE frequency.
Returned Data Format
<nr2>
Query Example
PULS:FREQ:MIN?
1200.0000