Quick Guide
XFCT 1600/1608/1616
Optical termination box
Congratulations, you have just purchased a product with Intelbras quality and safety.
1. Care and Safety
»
Read the installation guide:
all safety and handling instructions should be
read before starting operations with the product and should be kept for future
reference.
»
Safety in transport and handling:
high pressure or violent vibrations are
not allowed during transport, storage, or use.
»
Technical assistance:
do not attempt to repair this product. Let all services
be done by our authorized service network.
»
Heed the warnings:
follow all the instructions indicated in the guide.
»
LGPD - General Law of Personal Data Protection:
Intelbras does not
access, transfer, capture, or perform any other type of personal data processing
resulting from this product.
2.
Technical Specifications
Maximum fusion capacity
12
Maximum derivation capacity
16
Maximum splitter capacity
1× 1×16 optical splitter (12 × 4 × 60 mm)
Ports
Main
2 individual main ports with support for Ø13 mm
Output
16
output
ports for 2 × 3 mm drop flat cable
3. Produ
c
t
3.1.
Available models
»
XFCT 1600:
aerial optical termination box without splitter
;
»
XFCT 1608:
aerial optical termination box with 1x8 SC/APC splitter
;
»
XFCT 1616:
aerial optical termination box with 1x16 SC/APC splitter
.
3.2.
Description
The Intelbras Optical Termination Box (OTB) is used as the termination point of the backbone
cable to connect with the drop cable to the network of FFT
X
communication systems. In the
OTB, fiber splicing, splitting and distribution can be done, providing adequate protection and
accommodation for FTTx network construction
.
With its completely closed structure made of
PC+ABS, the Intelbras OTB
provides
protection against humidity, dust, aging, and water,
with an IP 55
ingress protection rating.
3.3.
Features
»
Closed structure to accommodate splicing and optical connections
;
» Material: PC + ABS;
»
Ingress protection rating
: IP 55
;
»
Support for up to 16 SC adapters
;
»
Outdoor or indoor installation, and can be installed both on walls and on poles
;
»
Operat
ion
temperature range: -40 °C to +85 °C
;
»
Maximum relative humidity of the installation environment: 85%.
3.4.
Dimensions
A
293 mm
B
219 mm
C
84 mm
D
155 mm
E
82 mm
A
C
B
E
D
3.5.
XFCT Box Details
1
2
3
4
5
6
7
8
9
10
12
11
13
14
15
1
Cover
2
Lock protector
3
Latch
4
Sealing
5
Tray and mobile splices
6
Adapter holder
7
Adapter
8
Latch hinge for locking the
cover
9
Cover
latch
10
Base
11
Cable locking system
12
Passage for
uncutting cable
13
Box locking system
14
Support for PLC Mini-Module splitter
15
Grooves to fix the sleeves
3.6.
Accessories
A
B
F
G
H
E
D
C
A
10×
plastic ties
B
16×
fusion sleeves
C
4×
fixing screws
D
4×
plugs
E
1×
tube for conducting the loose tube
F
2×
parts for the
uncut cable
G
2×
screws to fix the support to the
uncut cable
H
2×
keys for closing the box