LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 305 of 463
Command Syntax
[SOURce:]PULSe:PHASe# < nr2 >, <cr>
Description
This command sets the initial PULSE phase angle for selected phase #
number. Only phase 2 (B) and 3 (C) are allowed.
Parameters
Phase No., < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
Parameter Format
<nr1>, <cr>
Example
PULS:PHAS1 245.0
Query Format
[SOURce:]PULSe:PHASe#?
Returned Data Format
<nr1>, <cr>
Query Example
PULS:PHAS1?
245.0000
Query Syntax
[SOURce:]PULSe:PHASe#:MINimum?
Description
This command returns the minimum permissible set value of the
initial PULSE phase angle for selected phase #
Returned Data Format
<nr1>
Query Example
PULS:PHAS1:MIN?
0.0000
Query Syntax
[SOURce:]PULSe:PHASe#:MAXimum?
Description
This command returns the maximum permissible set value of the
initial PULSE phase angle for selected phase #
Returned Data Format
<nr1>
Query Example
PULS:PHAS1:MAX?
360.000
Query Syntax
[SOURce:]PULSe:PHASe#:DEF?
Description
This command returns the default set value of the initial PULSE phase
angle for selected phase #
Returned Data Format
<nr1>
Query Example
PULS:PHAS2:DEF?
120.0000
PULS:PHAS3:DEF?
240.0000