LMX SERIES® OPERATION MANUAL
SECTION 4: Technical Specifications
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 46 of 463
4.10.6
305LMX AC Input
The Model 305LMX single-phase input voltages, required input currents at full rated load
and recommended service input currents are stated as below.
NO
INPUT VOLTAGE
INPUT CURRENT
RECOMMENDED SERVICE
1
100 Vac ±10%, 47-63 Hz
12 Arms
25 A
2
110 Vac ±10%, 47-63 Hz
12 Arms
25 A
3
120 Vac ±10%, 47-63 Hz
11 Arms
25 A
4
200 Vac ±10%, 47-63 Hz
6 Arms
15 A
5
208 Vac ±10%, 47-63 Hz
6 Arms
15 A
6
220 Vac ±10%, 47-63 Hz
6 Arms
15 A
7
230 Vac ±10%, 47-63 Hz
6 Arms
15 A
8
240 Vac ±10%, 47-63 Hz
6 Arms
15 A
4.10.7
308LMX AC Input
The Model 308LMX single-phase input voltages, required input currents at full rated load
and recommended service input currents are stated as below.
NO
INPUT VOLTAGE
INPUT CURRENT
RECOMMENDED SERVICE
1
100 Vac ±10%, 47-63 Hz
17 Arms
25 A
2
110 Vac ±10%, 47-63 Hz
16 Arms
25 A
3
120 Vac ±10%, 47-63 Hz
15 Arms
25 A
4
200 Vac ±10%, 47-63 Hz
9 Arms
25 A
5
208 Vac ±10%, 47-63 Hz
9 Arms
25 A
6
220 Vac ±10%, 47-63 Hz
8 Arms
15 A
7
230 Vac ±10%, 47-63 Hz
8 Arms
15 A
8
240 Vac ±10%, 47-63 Hz
8 Arms
15 A
4.10.8
312LMX AC Input
The Model 312LMX single-phase input voltages, required input currents at full rated load
and recommended service input currents are stated as below.
NO
INPUT VOLTAGE
INPUT CURRENT
RECOMMENDED SERVICE
1
100 Vac ±10%, 47-63 Hz
20 Arms
25 A
2
110 Vac ±10%, 47-63 Hz
18 Arms
25 A
3
120 Vac ±10%, 47-63 Hz
18 Arms
25 A
4
200 Vac ±10%, 47-63 Hz
11 Arms
15 A
5
208 Vac ±10%, 47-63 Hz
10 Arms
15 A
6
220 Vac ±10%, 47-63 Hz
10 Arms
15 A
7
230 Vac ±10%, 47-63 Hz
9 Arms
15 A
8
240 Vac ±10%, 47-63 Hz
9 Arms
15 A